Description
Contact us for pricing and complete specifications of the HAZMAT2008 flammable material and chemical storage storage unit. Most of our inventory is not available online, contact us for project-ready storage lockers and hazardous material storage buildings.
Have Questions? Let us know...
Flammable Storage Locker – HAZMAT2008
Two Hour Fire-Rated Storage Locker Overview
Two Hour Fire Rated Flammable Storage Locker
- HAZMAT2008 – FL 12′ x 8′ x 9′ Actual Dimensions
Exterior: 11’4” x 7’4” x 9’4” Interior: 10’0” x 6’0” x 7’6” - Structural Load Certification
Snow Load: 40 PSF Wind Load: 130 MPH Exposure C
Floor Load: 500 PSF Building Weight: 11,000 LBS
Full Storage: 30,000 LBS Seismic Category: C - Storage Capacity
Storage: 15 Drums / 60Total Sq Ft Sump Capacity:224.2 Gallons Load: 1000+ PSF - This building will store up to 15 Drums, 825 Gallons, or up to 1000 lbs PSF in compliance with OSHA, EPA, and NFPA chemical storage regulations. Each Hazardous Material Storage Locker by US Hazmat Rentals are proudly made in the USA with the highest grade American steel. This raw material quality and attention to detail ensures the building is free from rough edges, kinks and sharp bends throughout the manufacturing process which could otherwise reduce the strength of the steel to a value less than intended by the UL design. Each step of the meticulous manufacturing process is precision engineered so that all bends are made by controlled means ensuring uniformity and strength throughout each locker. Each of our welding procedures are designed in accordance with the American Welding Society and meet standards set forth by American Society for Testing and Materials (ASTM International). Every weld is applied in accordance with approved UL listed wall design for premium safety.
Access Doors
Access doors meet or exceed required standards and certifications
- This locker includes a UL classified and labeled, one and one-half hour (1-1/2) fire-rated 60″ double leaf steel door. This door is equipped with a UL listed self door closer, steel latch guard, surface slide bolt, positive pressure threshold, and an exterior UL listed keyed lock. It’s positioned in the center of the front wall of the storage unit for easy access to all sections of the interior storage compartment.
- With the structural founding being raised off the ground and the integrated spill containment system, the floor of the unit and the door are not flush on ground level. Each unit includes a heavy duty steel access ramp for usability and accessibility throughout the contract period or construction project.
Fire Suppression System
Adequate and accessible fire suppression systems
- An advanced fire suppression system is included with this unit design. The locker is delivered to you with a ready to use dry chemical fire suppression tank that is UL, ULC Listed and FM approved for class A, B and C fires. This system also features remote activation with integrated fusible link detection, a manual exterior pull station, and multiple interior discharge nozzles for maximum coverage in a flooding application. The included dry chemical agent storage tank is mounted in a weatherproof enclosure on the exterior locker. For added safety, this system is complete with an audible alarm.
Secondary Spill Containment
Secondary Hazardous Chemical Spill Containment System
- This locker provides integrated best in class secondary containment designed to prevent the external leakage of solid material or liquid chemicals outside the building’s containment area. This specifically designed containment system meets or exceeds EPA’s spill containment capacity. High strength flooring designed with open grating allows any material to quickly enter the sump so not to contaminate other storage items, or the building itself. This leak proof assembly features a deep welded steel floor grating, a large secondary containment sump, and a high density leak-proof sump liner is added for added chemical resistance and spill protection. Continuous galvanized steel floor grating runs wall to wall throughout the length of the building. Sump is meticulously fabricated utilizing continuous weld solid plate steel sheets. Furthermore, the entire secondary containment sump is coated with a chemical-resistant enamel. The locker’s flooring is designed and fabricated in accordance with the National Association of Architectural Metal Manufacturers (NAAMM) bar grating specifications.
Lighting Components
Explosion Proof Electrical Lighting
- Designed to safety store flammable and combustable material, the locker includes an explosion proof interior incandescent light fixture. This electrical lighting component is UL listed Class 1 Div 1 & 2 Groups C, D. Class 2 Div 1 & 2 Groups E, F, G. Class 3 Div 1, and rated for use where moisture, dirt, dust, corrosion and vibration may be present. Users may activate the light from the extra switch prior to opening the access door and without having to enter the building.
Electrical Specifications and Load Center
HAZMAT2008 Electrical Components
- Our UL Listed Single-Phase, 3 Wire, 120/240V 100 A electrical load center is housed by a rainproof, sleet-resistant, and ice-resistant outdoor grade enclosure. These units are designed for outdoor use to protect the enclosed equipment against the elements. They’ve been engineered to meet the requirements of Underwriters’ Laboratories (UL) as they apply to rainproof enclosures.
- All electrical equipment and its installation in our chemical storage locker in done so in accordance with the National Electrical Manufactures Association (NEMA), National Electrical Code (NEC), and National Fire Protection Association (NFPA) standards. This locker and its optional equipment is furnished with all motors, controls, interlocks and any other electrical components necessary for operation once a primary power supply is connected.
Mechanized Explosion Proof Electrical Ventilation System
Chemical Storage Approved Explosion Proof Ventilation
- This locker features an integrated pre-engeinered ventilation system designed for flammable storage compliance. This provides a minimum air circulation and return of one cubic foot per minute (CFM) of exhaust per square foot of floor area. The UL listed gravity air flow ventilation with 1-1/2 hour rated fire dampers and includes a UL listed 165 degree fusible link activation system. Dampers include louvers and screens to provide airflow and have a galvanized steel frame and curtain type galvanized steel blades. The location of the ventilation components are arranged to provide air movement across all areas of the floor to prevent accumulation of flammable vapors.
- The mechanical vent produces a minimum of 6 air changes per hour with exhaust from the storage unit directed to the atmosphere and not recirculated into compartment air. This explosion proof electromechanical ventilation system uses a UL Listed, Class I, Division 1, Group C and D compliant enclosed motor with non-static 12 inch diameter cast aluminum fan blade. External housing constructed of solid plate steel with an epoxy-coated exterior. The system is manually activated by operator with the exterior UL Listed fan switch prior to entering the safety storage unit.
Climate Control And Air Handling
Storage Locker Heating and Air Conditioned Climate Controls
- The HAZMAT2008 locker is lined with heavy gauge Galvalume steel sheeting. It is constructed with mineral fiber insulation in both the ceiling and walls for lasting safety and durability while maintaining an R value of R-11. The climate control system includes an explosion proof air conditioner and an explosion proof heater for proper storage of flammable materials that must maintain select temperate range.
- Explosion Proof Wall Mounted Air Conditioner
- Explosion Proof air conditioner is UL Listed, and Class I, Division 2, Group A, B, C & D complaint. There is an interior temperature controller with user-adjustable temperature settings allowing operator to properly store flammable liquids, combustibles.
- Explosion Proof Wall Mounted Heater
- The Convection Heater is also engineer explosion proof, and is UL Listed, Class 1, Division 1 & 2, Groups C & D; Zones 1 & 2, Groups IIA & IIB compliant.
*Images are for reference only. Please contact us for complete specifications for our available inventory. Please consult your local authority having jurisdiction to ensure your storage needs are met.
Reviews
There are no reviews yet.