CB2008 20' x 8' Non-Fire-Rated Chemical Storage Locker

The CB2008 is a 20' x 8' non-fire-rated chemical storage locker that stores up to 25 drums with 460 gallons of secondary spill containment. Renters use it for corrosives and oxidizers (segregated); pesticides, herbicides and fertilizers; and water treatment chemicals. Designed to help meet NFPA, EPA, OSHA and IFC requirements.

Capacity
Up to 25 drums
Spill sump
460 gal
Size
20' x 8'
Fire rating
Non-Fire-Rated

Full features, construction & components

CB2008 specifications

ModelCB2008
Fire ratingNon-Fire-Rated
Nominal size20' x 8'
Exterior (L x W x H)20'0" x 8'0" x 8'6"
Interior (L x W x H)19'4" x 7'8" x 7'3"
Drum capacity25 drums
Storage floor area144 sq ft
Spill sump capacity460 gallons
Snow load40 PSF
Wind load130 MPH, Exposure C
Floor load500 PSF
Building weight9,000 lbs

Standard

  • Ventilation
  • Secondary spill containment

Available options

Sized for

Common uses

  • Corrosives and oxidizers (segregated)
  • Pesticides, herbicides and fertilizers
  • Water treatment chemicals

Designed to help meet NFPA, EPA, OSHA and IFC requirements.

CB2008 features & components

This Non Fire Rated Chemical Storage Locker, HAZMATCB2008, is storage unit that measures 20′ long x 8′ wide x 8’6″ high. This locker is well equipped to handle a capacity of 25 drums, it has 144 Total Sq Ft of usable space for compliant hazardous chemical or material storage. The empty locker weighs about 9,000 pounds, is rated for a 40 PSF of snow, and can handle winds of 130 MPH . This specialty chemical storage locker follows all of the Federal, State, and Local standards for personal safety and it also complies with standards set by the Occupational Safety and Health Standards (OSHA), Environmental Protection Agency (EPA), and the National Fire Protection Association (NFPA).

Non fire-rated construction is designed for standard, non-flammable hazardous chemical storage. These units are designed to safely store Herbicides, Fungicide, Pesticide, Fertilizer, Paints, and other FM & EPA regulated Chemical Storage where applicable. Please consult OSHA, NFPA, FM, and EPA to ensure all local regulation and chemical storage compliance requirements at your facility are met. Contact us today to discuss your needs.

  

CB2008 overview

Non Fire Rated Chemical Storage Locker

  1. HAZMATCB2008 – FL 20′ x 8′ x 8′ Actual Dimensions
    Exterior: 20′ x 8′ x 8’6”       Interior: 19’4” x 7’8” x 7’3”
  2. Structural Load Certification
    Snow Load: 40 PSF                 Wind Load: 130 MPH Exposure C
    Floor Load: 500 PSF                 Building Weight: 9,000 LBS
  3. Storage Capacity
    Storage: 25 Drums / 144 Total Sq Ft Sump Capacity:460 Gallons
  4. This hazardous material and chemical storage building can hold up to 25 drums at 144 square feet, with a 460 gallon sump capacity.  These criteria meet the OSHA, EPA, and NFPA chemical storage regulations.  Each unit measures 8 feet wide, 20 feet long, and approximately 8’6” feet high.  Our chemical storage lockers are manufactured right here in the USA.  We only use the highest quality American steel, free of rough edges, kinks, and sharp bends.   Our attention to detail and use of high quality materials ensures that your building will be manufactured mistake-free, with its intended structural strength.  Each step in our manufacturing process has been refined to ensure uniformity in each building, as well as top quality work.  Our welding process was designed through the American Welding Society and meets the American Society for Testing Material’s (ATSM International) standards. For premium safety, all of our welds are in accordance with UL listed wall design.  Each building is also weather resistant.

Access Doors

Access doors meet or exceed enforced standards and certifications

  1. This unit has lockable double doors with cam closures, located on short end of Locker. Doors total 7’9’’ high x 7’5 ‘’ wide.
  2. Integrated with a spill containment system, this locker has been raised off the ground which makes the door and floor of the unit not flush with the ground. Included with the locker is a heavy duty access ramp for easy access during the contract period.

Secondary Spill Containment

Secondary Hazardous Chemical Spill Containment System

  1. This locker is integrated with a high quality secondary containment system to prevent the leakage of solid or liquid chemicals. Our containment system meets or exceeds the EPA’s spill containment capacity requirements. The heavy duty  open grate flooring system allows for chemicals to fall through the grate as to not contaminate other materials in the locker, and the locker itself. The leak proof design is assembled with  a deep welded steel floor grating, a large secondary containment sump, and a high density leak-proof sump liner. For added protection, the galvanized steel grating runs from wall to wall in the building, the sump is manufactured with solid plate sheets with continuous welds, and the secondary containment sump has been lined with a chemical resistant coating. This locker’s flooring has been designed and manufactured to meet with the specifications of the National Association of Architectural Metal Manufacturers (NAAMM).

Electrical Specifications and Load Center

HAZMATCB2008 Electrical Components

  1. Our electrical components are UL listed single phase, 3 wire, and has a 120/240V 100 electrical load center. The load center is mounted on the exterior of the locker encased with a rainproof, sleet-resistant, and ice-resistant outdoor grade enclosure. It has been designed to meet with all of the requirements of the Underwriters’ Laboratories.
  2. All of the installation of our electrical components in the chemical storage lockers are done within the regulations of the National Electrical Manufactured Association (NEMA), National Electrical Code (NEC), and he National Fire Protection Association. This locker is well equipped with all of the electrical and motor components necessary for operation once a power source has been supplied.

Lighting Components

Explosion Proof Electrical Lighting

  1. Our explosion proof electrical lighting is designed to work in conjunction with flammable materials. The lighting component is UL listed class 1, Div 1 & 2, and groups C and D. It is also listed as Class 2, Div 1 & 2, Groups E, F, G, and Class 3 Div 1 & 2. The lighting is specifically designed to be used around moisture, dirt, dust, corrosion, and vibrations. The explosion proof lighting can be activated  from an exterior switch prior to entrance in the building.

Mechanized Explosion Proof Electrical Ventilation System

Chemical Storage Approved Explosion Proof Ventilation

  1. This locker features a high quality ventilation system required for proper paint storage facilities. This system is designed to ventilate flammable storage areas with proper air turnover. It has a continuous minimum replacement of one cubic foot every minute. Our ventilation system is well equipped with a 3 hour fire dampers, UL listed 165 degree fusible link activation system, and a gravity flow ventilation system.
  2. The mechanical ventilation system moves about 6 full air changes every hour. This exhaust air is released above the locker as to not accidentally recirculate bad air. This explosion proof electromechanical ventilation system uses a UL Listed, Class I, Division 1, Group C and D compliant enclosed motor with non-static 12 inch diameter cast aluminum fan blade. This mechanism is externally mounted which can be manually operated with the exterior UL fan switch prior to entering the locker.

Climate Control And Air Handling

Storage Locker Heating and Air Conditioned Climate Controls

To ensure your facility meets storage requirements for most paints, thinners, and other material requiring a select temperature range. Our paint storage buildings are engineered with Explosion Proof Climate Control to ensure a steady and compliant storage environment of your hazardous materials.

  1. The HAZMATCB2008 locker interior is well-lined with heavy duty Galvalume steel sheeting. Mineral fiber insulation is installed in each building within the ceiling and walls which allows for the building to maintain an R value of R-11. The climate control system is explosion proof with an air conditioner and a heater that can maintain a specific temperature.
  2. Explosion Proof Wall Mounted Air Conditioner
    1. Explosion Proof air conditioner is UL Listed, and Class I, Division 2, Group A, B, C & D complaint. There is an interior temperature controller with user-adjustable temperature settings allowing operator to properly store flammable liquids, combustibles. It has a totally enclosed fan motor with stainless steel shaft to resist corrosion and a hermetically sealed overload and an exterior switch to prevent arcing.
  3. Explosion Proof Wall Mounted Heater
    1. The Forced Air Heater is engineer explosion proof, and is UL Listed, Class 1, Division 1 & 2, Groups C & D; Zones 1 & 2, Groups IIA & IIB compliant. It also includes a user-adjustable thermostat for temperature control.

*Images are for referencing purposes only. Make sure to contact us for complete specifications for our available inventory. Please consult your local authority having jurisdiction to ensure your storage needs are met.

Compare non-fire-rated models

ModelFire ratingSizeCapacitySpill sumpExterior (L x W x H)
CL0806Non-Fire-Rated8' x 6'Up to 6 drums133 gal7'0" x 5'0" x 8'5"
12-DrumNon-Fire-Rated—Up to 12 drums——
CB2008Non-Fire-Rated20' x 8'Up to 25 drums460 gal20'0" x 8'0" x 8'6"
CBC2008Non-Fire-Rated20' x 8'Up to 25 drums460 gal20'0" x 8'0" x 8'6"
CBMP2008Non-Fire-Rated20' x 8'Up to 25 drums460 gal20'0" x 8'0" x 8'6"
27-DrumNon-Fire-Rated—Up to 27 drums——
42-DrumNon-Fire-Rated—Up to 42 drums——
57-DrumNon-Fire-Rated—Up to 57 drums——
CL0808Non-Fire-Rated8' x 8'Contact us——

Other ratings: 2-hour fire-rated · 4-hour fire-rated

Frequently asked questions

Which options can I add to a chemical storage building?

Climate control, heating, air conditioning, freezer / refrigeration, lighting, shelving, spill-sump shelving, racking, and wet or dry fire suppression are available. Ventilation and secondary spill containment are standard.

Do you rent drums, totes or the chemicals?

No — we rent the storage building, locker or container. You supply the drums, totes, pails and other packaging.

Can I store IBC totes and pallets?

Yes. Tote and pallet buildings hold 1 to 36 totes or pallets across our fleet; the SL2008-4034 in this catalog holds 4 IBC totes with a pump and work area.

Which fire rating do I need?

It depends on what you store and how close the building sits to other structures and property lines. Your fire marshal or AHJ makes the call; send us your materials list and site layout and we will recommend a model.