Fertilizer and Pesticide Storage Locker HAZMAT CL0808

This None Fire Rated Flammable Storage Locker, HAZMAT CL0808 provides a securable and compliant hazmat chemical storage building. Unit should none fire rated, Intertek Warnock Hersey approved, FM Global Approved, lockable, climate controlled, and weatherproof. Storage unit should measure 8 feet wide, 30 feet long, and approximately 8 feet high. System capacity should allow for up to 42Drums at 168 square feet with a 4 gallons sump capacity. Storage unit must comply with all applicable federal, state, and local standards for personnel safety and the storage of flammable materials including Occupational Safety and Health Standards, and National Fire Protection Association Standard 30. Facility will be used by the storage activity for the entire duration of the contract period.

 

  Request A Quote     Free Storage Guide

Description

Fertilizer and Pesticide – HAZMAT CL0808

  1. Non Fire Rated Flammable Storage Locker
    1. HAZMATCL0808 – CL 8′ x 8′ x 9′ Actual Dimensions
      Exterior: 29’4” x 7’4” x 9’4”       Interior: 28’0” x 6’0” x 7’6”
    2. Structural Load Certification
      Snow Load: 40 PSF                 Wind Load: 130 MPH Exposure C
      Floor Load: 500 PSF                 Building Weight: 21,000 LBS
      Full Storage
      : 84,000 LBS         Seismic Category: C
    3. Storage Capacity
      Storage: 42 Drums / 168 Total Sq Ft Sump Capacity:627.4 Gallons   Load: 1000+ PSF
    4. This flammable material and flammable liquid storage building can hold up to 42 drums, 627.4 gallons, or up to 1000 lbs PSF. These criteria meet the OSHA, EPA, and NFPA chemical storage regulations. Each of our chemical storage lockers are manufactured in the USA with only the highest quality American steel. Our attention to detail and use of high quality materials ensures that your building will be manufactured without mistakes, and your building has its intended structural strength. Every step in our manufacturing process has been engineered to every degree which ensures uniformity and structural strength in each building. Our welding process has been designed through the American Welding Society and meets the American Society for Testing Material’s (ATSM International) standards. For premium safety, all of our welds are in accordance with UL listed wall design.

Access doors meet or exceed enforced standards and certifications

  1. The locker access door is fire-rated to three hours of intense flame with a 60″ double leaf steel door and a UL classification label. Equipped with a UL listed self door closer, surface slide bolt, positive pressure threshold , steel latch guard, and an exterior UL listed keyed lock, this door is sure to meet all of your needs. The door has been positioned in the center of the front wall for easy access to all of the interior compartment.
  2. Integrated with a spill containment system, this locker has been raised off the ground which makes the door and floor of the unit not flush with the ground. Included with the locker is a heavy duty access ramp for easy access during the contract period.

Adequate and accessible fire suppression systems

  1. This paint storage chemical storage building is equipped with state of the art fire suppression system. It has a ready-to-use 21 lb. dry chemical fire suppression tank that is UL, ULC listed and FM approved for the A, B, and C fire classes. This high quality system is also equipped with  remote activation with an integrated  fusible link detection, a manual exterior pull station , and multiple interior spray nozzles for complete coverage in a flooding activation. The dry chemical tank is mounted on the exterior of the locker, and comes with an audible alarm for added safety. The system is unarmed per D.O.T regulations and must be armed and certified by a licensed representative.

Secondary Hazardous Chemical Spill Containment System

  1. This locker is integrated with a high quality secondary containment system to prevent the leakage of solid or liquid chemicals. Our containment system meets or exceeds the EPA’s spill containment capacity requirements. The heavy duty  open grate flooring system allows for chemicals to fall through the grate as to not contaminate other materials in the locker, and the locker itself. The leak proof design is assembled with  a deep welded steel floor grating, a large secondary containment sump, and a high density leak-proof sump liner. For added protection, the galvanized steel grating runs from wall to wall in the building, the sump is manufactured with solid plate sheets with continuous welds, and the secondary containment sump has been lined with a chemical resistant coating. This locker’s flooring has been designed and manufactured to meet with the specifications of the National Association of Architectural Metal Manufacturers (NAAMM).

HAZMAT CL0808 Electrical Components

    • All electrical equipment and its installation shall be in accordance with NEMA and NEC standards. This locker and optional equipment shall be furnished with all motors, controls, interlocks and any other electrical components necessary for operation after connection of a primary power supply by the purchaser.  All electrical equipment shall be capable of operation on 240 VAC – single phase – 60 Hz.  All power components shall be sized to carry current at 230 Volts.  All power components shall be sized to carry current at 230 Volts and insulated.  This equipment shall be complete with all required overload and under voltage protection to suit the initial voltage specified and in all cases have controls of 120 Volts AC, or less.  All applicable equipment shall be present day “state of the art”, and all motors shall be manufacture rated energy efficient.
  1. All of the installation of our electrical components in the chemical storage lockers are done within the regulations of the National Electrical Manufactured Association (NEMA), National Electrical Code (NEC), and he National Fire Protection Association. This locker is well equipped with all of the electrical and motor components necessary for operation once a power source has been supplied.

Explosion Proof Electrical Lighting

  1. Our explosion proof electrical lighting is designed to work in conjunction with flammable materials. The lighting component is UL listed class 1, Div 1 & 2, and groups C and D. It is also listed as Class 2, Div 1 & 2, Groups E, F, G, and Class 3 Div 1 & 2. The lighting is specifically designed to be used around moisture, dirt, dust, corrosion, and vibrations. The explosion proof lighting can be activated  from an exterior switch prior to entrance in the building.

Chemical Storage Approved Explosion Proof Ventilation

  1. This locker features a high quality ventilation system required for proper paint storage facilities. This system is designed to ventilate flammable storage areas with proper air turnover. It has a continuous minimum replacement of one cubic foot every minute. Our ventilation system is well equipped with a 1-1/2 hour fire dampers, UL listed 165 degree fusible link activation system, and a gravity flow ventilation system.
  2. The mechanical ventilation system moves about 6 full air changes every hour. This exhaust air is released above the locker as to not accidentally recirculate bad air. This explosion proof electromechanical ventilation system uses a UL Listed, Class I, Division 1, Group C and D compliant enclosed motor with non-static 12 inch diameter cast aluminum fan blade. This mechanism is externally mounted which can be manually operated with the exterior UL fan switch prior to entering the locker.

Storage Locker Heating and Air Conditioned Climate Controls

To ensure your facility meets storage requirements for most paints, thinners, and other material requiring a select temperature range. Our paint storage buildings are engineered with Explosion Proof Climate Control to ensure a steady and compliant storage environment of your hazardous materials.

  1. The SL3008 locker interior is well-lined with heavy duty Galvalume steel sheeting. Mineral fiber insulation is installed in each building within the ceiling and walls which allows for the building to maintain an R value of R-11. The climate control system is explosion proof with an air conditioner and a heater that can maintain a specific temperature.
  2. Explosion Proof Wall Mounted Air Conditioner
      • Air Conditioner, EP Electric Wall Mounted 20,000 BTU
        • Explosion Proof UL Listed, Class I, Division 2, Group A, B, C & D Air Conditioner (20,000 Btu/hr., 208/230VAC,10.0/10.9A, 1-Phase), One (1) Interior Temperature Controller with User Adjustable Temperature Settings. Totally Enclosed Fan Motor with Stainless Steel Shaft to Resist Corrosion and a Hermetically sealed Overload and an Exterior Switch to Prevent Arcing.
  3. Explosion Proof Wall Mounted Heater
      • STANDARD EP Heater – 34,200 BTU/hr Explosion Proof (240V, 1 Phase)
        • One (1) Forced Air Heater (34,200 BTU/hr.), 10KW, UL Listed, Class 1, Division 1 & 2, Groups C & D; Zones 1 & 2, Groups IIA & IIB, 240V Single Phase 31.3A. Includes temperature thermostat. Model FX5-240160-100-T.

Get in contact with us for more information on pricing and complete building specifications of the HAZMAT SL3008 flammable material and paint storage storage buildings. Most of our supply is not available online, so make sure to contact us for our complete hazardous material storage buildings.

*Images are for referencing purposes only. Make sure to contact us for complete specifications for our available inventory. Please consult your local authority having jurisdiction to ensure your storage needs are met.

Reviews

There are no reviews yet.

Be the first to review “Fertilizer and Pesticide Storage Locker HAZMAT CL0808”