4-Hour Fire-Rated

SL2008-4034 20' x 8' 4-Hour Fire-Rated Flammable Material Storage Building (tote)

The SL2008-4034 is a 20' x 8' 4-hour fire-rated flammable material storage building (tote) that holds 4 IBC totes with a pump and work area with 600 gallons of secondary spill containment. Renters use it for ibc tote storage with pump / work area; and flammable and combustible liquids. Designed to help meet NFPA, EPA, OSHA and IFC requirements.

Capacity
4 IBC totes + work area
Spill sump
600 gal
Size
20' x 8'
Fire rating
4-Hour Fire-Rated

Full features, construction & components

SL2008-4034 specifications

ModelSL2008-4034
Fire rating4-Hour Fire-Rated
Nominal size20' x 8'
Exterior (L x W x H)19'4" x 7'4" x 10'4"
Interior (L x W x H)18'0" x 6'0" x 8'3"
IBC tote capacity4 totes + pump / work area
Storage floor area108 sq ft
Spill sump capacity600 gallons
Snow load40 PSF
Wind load130 MPH, Exposure C
Floor load500 PSF
Building weight18,000 lbs

Standard

  • Ventilation
  • Secondary spill containment

Available options

Sized for

Common uses

  • IBC tote storage with pump / work area
  • Flammable and combustible liquids

Designed to help meet NFPA, EPA, OSHA and IFC requirements.

SL2008-4034 features & components

The HAZMATSL2008-4034 is a custom Four Hour Fire Rated Chemical Storage Locker.  This unit features a storage capacity of up to 4 Totes.  The interior compartment also has added space for pumps and a personnel work aream, for a total of 108 sq ft of space.  The building measures 19’4″ long x 7’4″ wide x 10’4″ high.  The sump capacity of this unit is 600 gallons, and the building weighs approximately 18,000 pounds while empty.  The locker is rated for 40 PSF of snow and can withstand winds of up to 130 MPH.  This flammable storage unit comes well equipped with numerous safety features, including an electromechanical gravity flow ventilation system to provide clean air, explosion proof air conditioning and heating units for climate control, fire-resistant floor, walls, and ceiling, and a state of the art fire suppression system.

This specially engineered HAZMAT building is compliant with all applicable federal, state and local chemical storage regulations.  It also meets the Occupational Safety and Health Standards (OSHA), Environmental Protection Agency (EPA) and National Fire Protection Association’s (NFPA) chemical storage standards.

  

Flammable Storage Building – HAZMATSL2008-4034

SL2008-4034 overview

Four Hour Fire Rated Flammable Storage Building

  1. HAZMATSL2008-4034 – SL 20′ x 8′ x 8′ Actual Dimensions
    Exterior: 19’4” x 7’4” x 10’4”       Interior: 18’0” x 6’0” x 8’3”
  2. Structural Load Certification
    Snow Load: 40 PSF                 Wind Load: 130 MPH Exposure C
    Floor Load: 500 PSF                 Building Weight: 18,000 LBS
  3. Storage Capacity
    Storage: 4 Totes and Personnel Work Area / 108 Total Sq Ft   Sump Capacity: 600 Gallons
  4. This four hour fire rated chemical storage building, the HAZMAT SL2008-4034, allows for storage of up to 4 Totes and includes an area for pumps, at a total of 108 square feet.  The sump capacity is 600 gallons.  US Hazmat Rentals furnishes all of our custom flammable or combustible material storage building in the USA.  We use only the highest quality materials, including first-rate American steel that is always free of kinks, sharp bends, and rough edges.  All steel bends are made via controlled means, allowing the steel to maintain proper structural strength as well as guaranteeing uniformity in each plate.  Each step in our manufacturing process is being constantly refined to ensure optimum durability and quality in all of our storage units.   Our unique attention to detail throughout the entire process ensures that your building will always be manufactured free of mistakes.
  5. The SL2008-4034 custom unit is lockable, climate controlled, and weatherproof.    All above criteria are in compliance with OSHA, EPA, and NFPA chemical storage regulations.  In addition, our welding procedures are designed in accordance with the American Welding Society and meet standards set forth by the American Society for Testing and Materials (ASTM International).  Every weld is applied in accordance with approved UL listed wall design for premium safety.

Access Doors

Access doors meet or exceed enforced standards and certifications

  1. The locker access door is fire-rated to three hours of intense flame with a 60″ double leaf steel door and a UL classification label. Equipped with a UL listed self door closer, surface slide bolt, positive pressure threshold , steel latch guard, and an exterior UL listed keyed lock, this door is sure to meet all of your needs. The door has been positioned in the center of the front wall for easy access to all of the interior compartment.
  2. Integrated with a spill containment system, this locker has been raised off the ground which makes the door and floor of the unit not flush with the ground. Included with the locker is a heavy duty access ramp for easy access during the contract period.

Fire Suppression System

Dry Chemical Fire Suppression
Dry Chemical Fire Suppression Pre-engineered Fire Suppression System.
Dry chemical fire suppression designed for class A, B, and C fires. Equipped with fusible link detection for Remote Annunciation and a manual pull station. System is UL, ULC listed and FM approved. See How It Works

Adequate and accessible fire suppression systems

  1. This paint storage chemical storage building is equipped with state of the art fire suppression system. It has a ready-to-use 21 lb. dry chemical fire suppression tank that is UL, ULC listed and FM approved for the A, B, and C fire classes. This high quality system is also equipped with  remote activation with an integrated  fusible link detection, a manual exterior pull station , and multiple interior spray nozzles for complete coverage in a flooding activation. The dry chemical tank is mounted on the exterior of the locker, and comes with an audible alarm for added safety. The system is unarmed per D.O.T regulations and must be armed and certified by a licensed representative.

Secondary Spill Containment

Secondary Hazardous Chemical Spill Containment System

  1. This locker is integrated with a high quality secondary containment system to prevent the leakage of solid or liquid chemicals. Our containment system meets or exceeds the EPA’s spill containment capacity requirements. The heavy duty  open grate flooring system allows for chemicals to fall through the grate as to not contaminate other materials in the locker, and the locker itself. The leak proof design is assembled with  a deep welded steel floor grating, a large secondary containment sump, and a high density leak-proof sump liner. For added protection, the galvanized steel grating runs from wall to wall in the building, the sump is manufactured with solid plate sheets with continuous welds, and the secondary containment sump has been lined with a chemical resistant coating. This locker’s flooring has been designed and manufactured to meet with the specifications of the National Association of Architectural Metal Manufacturers (NAAMM).

Electrical Specifications and Load Center

HAZMATSL2008-4034 Electrical Components

  1. Our electrical components are UL listed single phase, 3 wire, and has a 120/240V 100 electrical load center. The load center is mounted on the exterior of the locker encased with a rainproof, sleet-resistant, and ice-resistant outdoor grade enclosure. It has been designed to meet with all of the requirements of the Underwriters’ Laboratories.
  2. All of the installation of our electrical components in the chemical storage lockers are done within the regulations of the National Electrical Manufactured Association (NEMA), National Electrical Code (NEC), and he National Fire Protection Association. This locker is well equipped with all of the electrical and motor components necessary for operation once a power source has been supplied.

Lighting Components

Explosion Proof Electrical Lighting

  1. Our explosion proof electrical lighting is designed to work in conjunction with flammable materials. The lighting component is UL listed class 1, Div 1 & 2, and groups C and D. It is also listed as Class 2, Div 1 & 2, Groups E, F, G, and Class 3 Div 1 & 2. The lighting is specifically designed to be used around moisture, dirt, dust, corrosion, and vibrations. The explosion proof lighting can be activated  from an exterior switch prior to entrance in the building.

Mechanized Explosion Proof Electrical Ventilation System

Chemical Storage Approved Explosion Proof Ventilation

  1. This locker features a high quality ventilation system required for proper paint storage facilities. This system is designed to ventilate flammable storage areas with proper air turnover. It has a continuous minimum replacement of one cubic foot every minute. Our ventilation system is well equipped with a 3 hour fire dampers, UL listed 165 degree fusible link activation system, and a gravity flow ventilation system.
  2. The mechanical ventilation system moves about 6 full air changes every hour. This exhaust air is released above the locker as to not accidentally recirculate bad air. This explosion proof electromechanical ventilation system uses a UL Listed, Class I, Division 1, Group C and D compliant enclosed motor with non-static 12 inch diameter cast aluminum fan blade. This mechanism is externally mounted which can be manually operated with the exterior UL fan switch prior to entering the locker.

Climate Control And Air Handling

Storage Locker Heating and Air Conditioned Climate Controls

To ensure your facility meets storage requirements for most paints, thinners, and other material requiring a select temperature range. Our paint storage buildings are engineered with Explosion Proof Climate Control to ensure a steady and compliant storage environment of your hazardous materials.

  1. The HAZMATSL2008-4034 locker interior is well-lined with heavy duty Galvalume steel sheeting. Mineral fiber insulation is installed in each building within the ceiling and walls which allows for the building to maintain an R value of R-11. The climate control system is explosion proof with an air conditioner and a heater that can maintain a specific temperature.
  2. Explosion Proof Wall Mounted Air Conditioner
    1. Explosion Proof air conditioner is UL Listed, and Class I, Division 2, Group A, B, C & D complaint. There is an interior temperature controller with user-adjustable temperature settings allowing operator to properly store flammable liquids, combustibles. It has a totally enclosed fan motor with stainless steel shaft to resist corrosion and a hermetically sealed overload and an exterior switch to prevent arcing.
  3. Explosion Proof Wall Mounted Heater
    1. The Forced Air Heater is engineer explosion proof, and is UL Listed, Class 1, Division 1 & 2, Groups C & D; Zones 1 & 2, Groups IIA & IIB compliant. It also includes a user-adjustable thermostat for temperature control.

*Images are for referencing purposes only. Make sure to contact us for complete specifications for our available inventory. Please consult your local authority having jurisdiction to ensure your storage needs are met.

Compare 4-hour fire-rated models

ModelFire ratingSizeCapacitySpill sumpExterior (L x W x H)
SL10084-Hour Fire-Rated10' x 8'Up to 12 drums179.4 gal9'4" x 7'4" x 9'4"
HC20084-Hour Fire-Rated20' x 8'Up to 27 drums403.4 gal19'4" x 7'4" x 9'4"
SL20084-Hour Fire-Rated20' x 8'Up to 27 drums403.4 gal19'4" x 7'4" x 9'4"
SL22084-Hour Fire-Rated22' x 8'Up to 30 drums448.2 gal21'4" x 7'4" x 9'4"
SL30084-Hour Fire-Rated30' x 8'Up to 42 drums627.4 gal29'4" x 7'4" x 9'4"
HC40084-Hour Fire-Rated40' x 8'Up to 57 drums851.4 gal39'4" x 7'4" x 9'4"
SL32104-Hour Fire-Rated32' x 10'Up to 60 drums897.1 gal31'4" x 9'4" x 9'4"
HC30084-Hour Fire-Rated30' x 8'Contact us——
SL2008-40344-Hour Fire-Rated20' x 8'4 IBC totes + work area600 gal19'4" x 7'4" x 10'4"

Other ratings: Non-fire-rated · 2-hour fire-rated

Frequently asked questions

Which options can I add to a chemical storage building?

Climate control, heating, air conditioning, freezer / refrigeration, lighting, shelving, spill-sump shelving, racking, and wet or dry fire suppression are available. Ventilation and secondary spill containment are standard.

Do you rent drums, totes or the chemicals?

No — we rent the storage building, locker or container. You supply the drums, totes, pails and other packaging.

Can I store IBC totes and pallets?

Yes. Tote and pallet buildings hold 1 to 36 totes or pallets across our fleet; the SL2008-4034 in this catalog holds 4 IBC totes with a pump and work area.

Which fire rating do I need?

It depends on what you store and how close the building sits to other structures and property lines. Your fire marshal or AHJ makes the call; send us your materials list and site layout and we will recommend a model.

Talk to a specialist

Get a quote for the SL2008-4034

Tell us what you need and where it is going. We reply within one business day with availability, lead time and a rental quote. In-stock units ship in days with rush processing; turnkey delivery and pickup are quoted per site.

Call 888-264-2449

Free Consultation

Tell Us What You Need

On submit you agree to all Terms and Privacy Policy.

Or call 888-264-2449 · Mon–Fri 8AM–5PM